Safety light curtains are electro-sensitive protective devices designed to stop hazardous machine motion when a person enters a protected area. Their effectiveness, however, depends not only on the selected device but also on correct positioning. A light curtain installed too close to a hazard may detect the operator but still leave insufficient time for the machine to stop.
1. How safety light curtains work
A safety light curtain uses an emitter and a receiver to create a protected field of infrared beams. When one or more beams are interrupted, the safety-related control system must initiate the required safe response. Device selection must consider the application, required performance, detection capability, environmental conditions and the overall machine risk assessment.
2. Safety distance according to ISO 13855:2024
The minimum distance between the detection zone and the hazardous area must account for the time needed to detect the person and bring the hazardous movement to a safe condition. A practical representation of the calculation is:
S = (K × T) + DDS + Z
where S is the minimum safety distance, K is the approach speed, T is the total system stopping time, DDS is the additional distance related to the detection capability and protective-device arrangement, and Z represents additional allowances required by the application and risk assessment. The actual installation must always be validated against the applicable clauses and configuration requirements of ISO 13855:2024.
3. Total stopping time matters
The value of T is not only the response time stated on the light-curtain datasheet. It must include the response time of the protective device, safety logic and output devices, plus the actual stopping time of the machine. Where stopping performance can deteriorate, the design and validation process must consider that variation. Stopping time should therefore be measured on the real machine and periodically verified.
4. Example — mechanical press
For a press with a relatively short stopping time and a suitably selected light curtain, the calculated minimum distance in our example is 420 mm. This value is meaningful only if the stopping-time measurement, detection capability, mounting arrangement and possibility of reaching over, under or around the protective field have all been verified.
5. Example — textile calender
A textile calender can present a drawing-in or crushing hazard between rotating cylinders. Because stopping times can be significantly longer than on a press, the required distance can increase rapidly. In the example analysed, the initial calculation gives 1,780 mm; after applying the appropriate configuration and validated parameters, the reference value becomes 1,424 mm. This illustrates why a light curtain cannot simply be mounted where it is most convenient for production.
6. Example — rotating coil stands
For stands or equipment rotating a coil, access to the danger zone and the time required for hazardous movement to stop can produce even greater distances. In our example the values are 3,100 mm and 2,480 mm, depending on the validated configuration. Where such distances are impractical, the answer is not to arbitrarily reduce S: the safeguarding concept must be redesigned, for example by changing access geometry, reducing stopping time or using an alternative protective solution supported by the risk assessment.
7. Selecting the device and auditing the installation
Solutions available on the market include product families such as ReeR EOS4, KEYENCE GL-V / GL-R and SICK deTec4. Selection should not be based on brand alone. Compare safety performance, detection capability, response time, protected height, operating range, muting/blanking needs, diagnostics, environmental resistance and integration with the safety-related control system.
During an audit, verify at least: the documented risk assessment; declared detection capability; measured stopping time; calculation of S; actual installed distance; prevention of reaching over, under, around or behind the protective field; reset and restart logic; bypass/muting controls; periodic functional testing; and evidence that changes to tooling, speed, controls or braking performance have triggered reassessment.
8. Standards and key takeaway
The safeguarding design should be considered within the machinery risk-reduction process and the applicable requirements for electro-sensitive protective equipment. Key references include ISO 13855:2024 for positioning safeguards with respect to the approach of the human body, ISO 12100 for machinery risk assessment and risk reduction, and the applicable parts of IEC 61496 for electro-sensitive protective equipment.
Key takeaway: a safety light curtain is effective only when the complete safety function is correctly engineered. Measure the real stopping time, calculate the required distance, verify access paths and validate the installation on the machine.
Disclaimer: This best practice is intended for general technical guidance and does not replace a machine-specific risk assessment, the manufacturer’s instructions, validation of the safety function or consultation of the complete applicable standards and legal requirements.